Loadcell HBM Z6FD1 -100kg
Maximum capacities: 5 kg … 1 t
Load cells and mounting aids made of rust-resistantmaterials
Legal for trade up to 6000 parts, test report toOIML R60
Approval as per NTEP III M5000 (USA & Canada)
Six-wire configuration
Optimized for parallel connection
Options: Explosion protection versions as per ATEX,IECEx and FM (US/CA)
Available with M12x1 male connector as (K-)Z6-P
Optional: Available with flexible (and space-saving)drag chain cable
Available as LCMC measurement chain with smartoption (IO-Link),
With digital option (CANopen or RS-485), with analog option (4 … 20 mA or 0 … 10 V)
| Model | Z6FD1 | |
| Rated Capacity (kgf) | 10, 20, 30, 50, 100, 200, 500 | |
| Accuracy Class According to OIML-R-60 | OIML | |
| Max. Number of Verification Intervals | D1 – 3000 | |
| Y= Emax/Vminh | ||
| Rate Output mV/V | 2 | |
| Tolerance on Rate Output mV/V | +1 ~ – 0.1 | |
| Temperature coefficient of sensivity %RO | ± 0.0500 | |
| Relative reversibility Error %RO | ± 0.0500 | |
| Non – linearity %RO | ± 0.0500 | |
| Zero Creep for 30min %RO | ± 0.0490 | |
| Limit Load % Emax | 150 | |
| Limit lateral Loading% Emax | 100 | |
| Breaking Load % Emax | 300 | |
| Excitation Voltage | Recommended (V) | 5 |
| Maximum (V) | 12 | |
| Resistance | Input (Ω) | 350 ~ 480 |
| Output (Ω) | 356 ± 0.2 | |
| Insulation (MΩ) | > 1.000 | |
| Compensated Temperature Range 0C | -10 ~ +40 | |
| Operating Temperature Range 0C | -30 ~ +70 | |
| Material | Stainless steel | |
| Cable Specification | ø 5.4 x 6P x 3m | |
| IP | 68 | |