Loadcell HBM PW15PH

 Maximum capacities 10 … 100 kg

 Stainless steel

 High ration of minimum verification interval Y

 Meets EMC guidelines

 M12 connection cable (aseptic) and other optionsavailable

Model PW15PH
Rated Capacity (kgf) 10, 20, 50, 100
Accuracy Class According to OIML-R-60 OIML
Max. Number of Verification Intervals C3 – 3000
Y= Emax/Vmin 10000
Rate Output mV/V 2.0 ± 0.2
Tolerance on Rate Output mV/V  ± 0.1
Temperature coefficient of sensivity %RO ± 0.0166
Relative reversibility Error %RO ± 0.0166
Non – linearity %RO ± 0.0166
Zero Creep for 30min %RO ± 0.0175
Limit Load % Emax 150
Limit lateral  Loading% Emax 100
Breaking Load % Emax 300
Excitation Voltage Recommended (V)  5
Maximum (V) 12
Resistance                        Input (Ω) 300  ~ 500
Output (Ω) 300  ~ 500
Insulation (MΩ) > 1.000
Compensated Temperature Range 0C -10 ~ +40
Operating Temperature Range 0C -10 ~ +50
Material Stainless steel
Cable Specification ø 5.4 x 6P x 5m
IP 68/69k