Loadcell HBM SP4MI

 Well known SP4M load cell with integrated IO-Linksensor communication

 IO-Link interface brings several advantages such assmart functions (preprocessing of data, selfmonitoring and warnings), bidirectional sensor communication, and easy installation

Model SP4MI
Rated Capacity (kgf) 1, 3, 5, 7, 10, 15, 20, 30, 50, 75, 100, 150, 200
Accuracy Class According to OIML-R-60 OIML
Max. Number of Verification Intervals C3 – 3000
Y= Emax/Vmin 10000
Rate Output mV/V 2
Tolerance on Rate Output mV/V  ± 0.1
Temperature coefficient of sensivity %RO ± 0.0170
Relative reversibility Error %RO ± 0.0170
Non – linearity %RO ± 0.0166
Zero Creep for 30min %RO ± 0.0166
Limit Load % Emax 150
Limit lateral  Loading% Emax 100
Breaking Load % Emax 300
Excitation Voltage Recommended (V)  5
Maximum (V) 12
Resistance                        Input (Ω) 350  ~ 480
Output (Ω) 356  ±  0.12
Insulation (MΩ) > 1.000
Compensated Temperature Range 0C -10 ~ +40
Operating Temperature Range 0C -10 ~ +50
Material Aluminum
Cable Specification ø 5.4 x 4P x 3m
IP 67