Loadcell ZEMIC HM9B

 Nickel plated alloy steel IP68 dual shear beam load cell

 Hermetically sealed

 Suitable for truck, track, hopper and other electronic weighing devices

 Current calibrated (SC-option)

 High accuracy

Model HM9B
Rated Capacity (tf) 10, 20, 25, 30, 40, 50
Accuracy Class  C3 – 3000
Rate Output mV/V 2.0 ± 0.002
Combined Error %RO ± 0.020
Creep Error (30 minutes) %RO ± 0.02
Temp. Effect on zero %S/10 0C (ZTC) ± 0.02
Temp. Effect on sensitivity %S/10 0C (STC) ± 0.02
Zero Balance %RO ± 1.0
Safe Overload % Emax 150
Maximum Overload % Emax 300
Excitation Voltage Recommended (V) 5 ~ 12
Maximum (V) 18
Resistance                        Input (Ω) 700 ± 7
Output (Ω) 703 ± 4
Insulation (MΩ) > 5.000
Compensated Temperature Range 0C -35 ~ +65
Operating Temperature Range 0C -40 ~ +80
Material Nickel Plated alloy steel
Cable Specification ø 5.5 x 4P x 16m
IP 68