Loadcell UTILCELL 300

Bending beam load cell

Fully Stainless Steel

3000 divisions OIML R60 class C *

Hermetically sealed, fully welded

Protected IP 68 (EN 60529)and IP 69K (ISO 20653)

Available in version (optional) Zone 0-1-2 (gas) and 20-21-22 (dust)

Model 300
Rated Capacity (kgf) 5, 10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 500
Accuracy Class  C3 – 3000
Rate Output mV/V 2.0 ± 0.1%
Total error %RO ± 0.017
Repeatability %RO ± 0.015
Temp. Effect on zero %S/10 0F ± 0.01
Temp. Effect on sensitivity %S/10 0F ± 0.006
Zero Creep for 30min %RO ± 0.016
Minimum dead load % Emin 0
Service loadc % Emax 150
Safe load limit % Emax 200
Excitation Voltage Recommended (V) 10
Maximum (V) 15
Resistance                        Input (Ω) 400 ± 20
Output (Ω) 350 ± 3
Insulation (MΩ) > 5.000
Compensated Temperature Range 0C -10 ~ +40
Operating Temperature Range 0C -30 ~ +70
Material Stainless steel 
Cable Specification ø 4 x 4P x 3m
IP 68/69k